TE Connectivity Ltd
|
| Part No. |
306027-6 306027-7 306027-9
|
| OCR Text |
...te die can then be placed in a vise with light pressure for gaging. 5. with the wire barrel dies bottomed, check the wire barrel crimp die closure using the proper plug gage. hold the gage in a straight alignment with the die closure ... |
| Description |
This instruction sheet provides application instructions, maintenance, and inspection procedures for PIDG STRATO-THERM
|
| File Size |
299.48K /
5 Page |
View
it Online |
Download Datasheet
|
| |
|
 |
TE Connectivity Ltd
|
| Part No. |
306209-2
|
| OCR Text |
...trol or coupling and place in a vise. use a suitable material to protect the finish on the head. 2. remove the setscrew (item 2) that secures the head assembly to the cylinder. 3. turn the head assembly counterclockwise to remove it ... |
| Description |
Hydraulic Crimping Head, PN 69067
|
| File Size |
280.12K /
6 Page |
View
it Online |
Download Datasheet
|
|

Price and Availability
|